Description

The Volume Ratio (Fidelity) examine metric is available when at least one block is selected for Examine. This metric is compatible with the Fidelity Adjacent Cell Volume Ratio metric.

For a given cell i, the volume ratio with a neighboring cell j is computed as follow:

ACVRj = max [Vi/Vj, Vj/Vi]

where:

ACVRj = Adjacent cell volume ratio between cells i and j
Vi = Volume of cell i
Vj = Volume of the adjacent cell j

The final volume ratio for cell i is computed by taking the maximum of all the volume ratios computed for each adjacent cell j:

ACVR = max [ACVRj]

This function is calculated across entity boundaries when adjacent entities are also selected for Examine.

 

Tip: The Volume Ratio function is an excellent diagnostic for finding cell size discontinuities at block interfaces.